ZigBee Module
Data Loggers
DataNet: High-end Logger
Bluetooth Data Logger
USB Data Logger
Wireless Data Logger
8-Channel DaqPRO
Temperature 10-bit
Temp./Humidity 10-bit
Temperature 8-bit
Temp./Humidity 8-bit
Software & Sensors
Sensors
Accessories
 

DaqPRO Software

DAQLAB™Powerful analysis software for Windows® 95/98/2000/XP/Vista

Everything in the Palm of your Hand

DaqLab provides advanced data analysis and processing. This innovative program enables the user to operate and configure all the DaqPRO functionality. DaqPRO works as a stand alone data logger, as well as connecting to the PC.

Download DaqPRO Software

Software Highlights
  • Fast data download from DaqPRO
  • Data displayed in numeric or graphic displays
  • Graphic analysis tools such as zoom and markers
  • Storage of selected data on disk files
  • Hard copy printing of collected data
  • Direct data export to Excel
  • Online retrieval and display of data in realtime
  • Incorporates advanced data processing functions
  • Enables set-up and calibration of DaqPRO on the go

DAQPRO Accessories 
  • Carrying case
  • NTC temperature probe
  • Solar cell and battery for field data logging
  • Weather box complies with the IP-67 standard for protecting DAQPRO while working in field applications

 

DAQPRO Sensors 

DAQPRO 5300 Inputs
8 differential inputs
Selectable range for each input:
0-20mA, 0-50mV, 0-10V, NTC, PT-100, Thermocouple,
Frequency (Input 1 only)

0-20mA input
Range: 0-20mA
Resolution: 0.4 µA
Accuracy: ±5µA
Loop impedance: 50Ω

0-50mV input
Range: 0-50mV
Resolution: 1µV
Accuracy: ±0.5%of reading
Input impedance: 200kΩ

0-10V input
Range: 0-10V
Resolution: 160µV
Accuracy: ±0.5% of reading
Input impedance: 200KΩ

Temperature NTC Input
NTC: 10KΩ resistor
Range: -25 – 110ºC
Resolution: 0.03ºC
Accuracy: ±1% of reading

Temperature PT-100
Range: -200 – 400ºC
Resolution: 0.1ºC (7mΩ)
Accuracy: ±0.5% of reading

The DAQ-PRO offers up to 8 PT-100 2 wire channels or 4 PT-100 3 wire Channels.

Temperature Thermocouple J
Range: -300 – 1500ºC
Resolution: 0.1ºC (1µV)
Accuracy: ±0.5% of reading
Cold junction compensation error: ±0.3ºC

Temperature thermocouple K
Range: -250 – 1100ºC
Resolution: 0.1ºC (1µV)
Accuracy: ±0.5% of reading
Cold junction compensation error: ±0.3ºC